juno106-

 

2. DCO CV OFFSET

(MODULE 8OARD)

 

Test instrument: Voltmeter (1mV resolution)

 

Test point:

Key assignment:

 

TP3

POLY 1 (UNISON during test mode).

 

2-1. Press MIDI CH button; D/A converter turns its output to OV.

 

CAUTION

 

Pressing any key on the keyboard releases MIDI CH, letting the D/A to develop voltage according to that key. Press MIDI CH again to defeat the key voltage.

 

2-2. Adjust VR33 for OV reading.

2-3. Leave MIDI CH ON for the next adjustment 3.

 

3. VGA BIAS

(MODULE BOARD)

 

Test instrument: Test point:

Key assignment:

 

Voltmeter (1mV resolution)

TP7

POLY 1 (UNISON during test

mode).

 

3-1. Press MIDI CH. Refer to "CAUTION in 2-1". 3-2. Adjust VR34 for a reading within +0.25V to

+0.27 V.

 

4. VGA OFFSET

(MODULE BOARD)

 

Test instrument: Test point.

BANK:

Key assignment:

 

Oscilloscope

TP8 (CH1) to TP13 (CH6)

1

POLY 1 (UNISON during test

mode)

 

4-1. Adjust the following trimmers, respectively, for the minimum thumps.

CH  

VR NO. 30

CN NO 1

 

25 20 15 10 5 2 3 4 5 6