ADJUSTEMENT

Adjustment must be performed in the order listed below.

POWER SUPPLY BOARD

ENTERING TEST MODE

MODULE BOARD

JACK BOARD

CHECKING MIDI FUNCTION

CAUTION

Allow at least 10 minutes for warmup period; mandatory upon VCF adjustments.

1. DC SUPPLY VOLTAGES

(POWER SUPPLY BOARD)

CAUTION

Any slight adjustment on this board must be followed by a complete adjustment of the rest. Do not touch the trimmers inadvertently before checking the test points for voltage.

Test instrument: Digital voltmeter with 10mV resolution.

1-1. Adjust VR1 for – 15V+ 10mV at pl. 1-2. Adjust VR2 for +5V + 10mV at Qb. 1-3. Verify +15V + 0.8V at Qc.

1-4. Verify +5V + 0.5V at Qd.

The following adjustments can be performed with the aid of Test Program stored in the CPU on the CPU Board.

To enter the test mode, hold KEY TRANSPOSE down and turn the JUNO-106 ON; the display window will

read – _ indicating that the unit is in the test mode. During the test mode, each switch serves as follows: